Where to take readings

Take readings at each of these locations, recording temperature, %RH, humidity ratio (gpk) and dew point for every one. Compare dew point with the wet surface.

Outside

  • Temperature
  • %RH
  • Humidity ratio (gpk)
  • Dew point

Affected area

  • Temperature
  • %RH
  • Humidity ratio (gpk)
  • Dew point

Dehumidifier output

  • Temperature
  • %RH
  • Humidity ratio (gpk)
  • Dew point

HVAC output, if used

  • Temperature
  • %RH
  • Humidity ratio (gpk)
  • Dew point

Unaffected area

  • Temperature
  • %RH
  • Humidity ratio (gpk)
  • Dew point

Comparison and analysis

  • Compare dew point against surface temperature to determine evaporation potential.
  • Evaluate vapour pressure differentials between the wet material surface and the ambient air, and between affected and unaffected zones.
  • Track changes over time to ensure drying targets are met.